SourceDirectional diffusion coefficients, that is, D1, D2, and D3, for the principal axis i = 1, 2, 3 of a unidirectional fibrous composite were determined by moisture absorption measurements. It was shown that the initial moisture absorption of a cured dry composite is non-Fickian and may relate to microstructural relaxation of internal stresses.
Moisture effusion rates of the specimens were also evaluated. Absorption-desorption kinetics over several cycles showed that there exists a damage mechnism in the composite which enhances moisture uptake from the dry state but does not enhance moisture release from the water-equilibrated state.