Work Item
ASTM WK96845
Revision of D2700-24c Standard Test Method for Motor Octane Number of Spark-Ignition Engine Fuel
Rationale
Discrepancy on Table A4.3 – Guide Table for Standard Knock Intensity at Standard Barometric Pressure (9/16 in. Venturi Dial Indicator Readings for Motor Octane Numbers). At 77.5 ON, table currently reads 0.745”, Based on the trend and surrounding values, correct value should be 0.645”.
Work Item Status
Date Initiated: 10-30-2025
Technical Contact: Stuart Brown
Item: 000
Ballot:
Status: