Revision of A494/A494M-24 Standard Specification for Castings, Nickel and Nickel Alloy
Rationale
The solution treatment in Table 2 for grade CY2Co is incorrect at 1175’C min and should be 1100’C min. The temperature for ’F will be corrected as well.