SYMPOSIA PAPER
Published:
01 January 1956
STP47579S
Automatic Impact Testing from Room Temperature to −236 C
SourceUsing liquid nitrogen and liquid helium as coolants, Charpy V-notch impact tests were conducted from room temperature to −236 C in an automatic device, which houses within a vacuum a complete impact machine and storage space for 105 specimens. Comparison impact tests of AISI 4340 steel conducted on both a conventional and the low-temperature impact machine to −195.8 C show that the device is a useful and accurate impact tool.
Author Information
DeSisto, Thomas, S.
Watertown Arsenal Laboratory, Watertown, Mass.
Related
Reprints and Permissions
Details
Developed by Committee: E01
Pages: 76–83
DOI: 10.1520/STP47579S
ISBN-EB: 978-0-8031-6912-8
ISBN-13: 978-0-8031-6536-6