Loading Tests on Full-Scale House Roofs
SourceEarlier loading tests on single roof frames had shown that many conven tional rafter-and-joist frames had failure loads well below the design snow loads specified in Canada. This suggested that either actual snow loads were lower than the design values or that the strength of individual roof frames do not indicate full strength of the complete roof. Consequently, a number of full-scale house roofs were load tested to failure in the laboratory to determine what additional strength is derived from the roof sheathing providing the roof with “folded plate action.” The results indicate that on the whole most roofs do not derive much extra strength from the sheathing.
Author Information
Thorburn, H., J.
National Research Council, Ottawa, Canada
Schriever, W., R.
National Research Council, Ottawa, Canada
Related
Reprints and Permissions
Details
Developed by Committee: E06
Pages: 67–77
DOI: 10.1520/STP45801S
ISBN-EB: 978-0-8031-6720-9
ISBN-13: 978-0-8031-6594-6