SYMPOSIA PAPER
Published:
01 January 1958
STP45047S
Investigation of Strain Gages for Long-Time Static Testing to 650 F
SourceResults are presented of a series of tests on the performance of HT 600 wire strain gages, at elevated temperatures over long periods of time. These gages showed no zero shift at temperatures below 650 F in over 300 hr of testing. The gage-to-gage consistency in the apparent strain versus temperature curves was within ±150 microinches per in. to 600 F.
Author Information
Yanowitz, Herbert
Foster Wheeler Corp., New York, N. Y.
Berman, Irwin
Foster Wheeler Corp., New York, N. Y.
Bleiweis, Alfred
Foster Wheeler Corp., New York, N. Y.
Related
Reprints and Permissions
Details
Developed by Committee: E28
Pages: 142–150
DOI: 10.1520/STP45047S
ISBN-EB: 978-0-8031-5950-1
ISBN-13: 978-0-8031-6104-7