SourceThe distribution of cathodic protection current between members of copper-steel and stainless steel-aluminum galvanic couples was found to vary by ratio of 940 to 0.05 as the relative areas were varied from 100:1 to 1:100. Polarization curves and the distribution of current are given. Above a 1:1 ratio of cathode to anode, cathodic protection does not appear to be practical.
Author Information
Compton, K., G.
University of Miami, Miami, Fla.
Related
Reprints and Permissions
Details
Developed by Committee: G01
Pages: 48–55
DOI: 10.1520/STP41396S
ISBN-EB: 978-0-8031-6045-3