SYMPOSIA PAPER
Published:
01 January 1985
STP39169S
Using Specifications to Avoid Chloride Stress Corrosion Cracking
SourceInsulated austenitic stainless steel above the critical temperature must be clearly identified to receive specific protection. Specify appropriate insulation and weather barrier material to prevent moisture entry. Proper application of insulation materials is an important part of the specification. Considerations for applying additional protection to austenitic stainless steel are dependent on the operating temperature and critical service of the insulated facility.
Author Information
Kalis, JW
E. I. du Pont De Nemours Company, Inc., Wilmington, DE
Related
Reprints and Permissions
Details
Developed by Committee: G01
Pages: 199–203
DOI: 10.1520/STP39169S
ISBN-EB: 978-0-8031-5591-6
ISBN-13: 978-0-8031-0416-7