SYMPOSIA PAPER
Published:
01 January 1974
STP38970S
Evaluation of New Ozone Monitoring Instruments by Measuring in Nonurban Atmospheres
SourceThis paper compares the response and sampling characteristics of chemiluminescent ozone-ethylene monitors, the ultraviolet ozone photometer, and a solid phase chemiluminescent ozone monitor. Gas phase ozone-ethylene monitors from different manufacturers were used in the study to determine the differences in the response and sampling characteristics of some commercially representative monitors. Comparisons included correlation among instruments, typical response characteristics, and a detailed study of maintenance requirements and calibration stability.
Author Information
Clark, TA
Environmental Protection Agency, National Environmental Research Center, Research Triangle Park, N. C.
Baumgardner, RE
Environmental Protection Agency, National Environmental Research Center, Research Triangle Park, N. C.
Stevens, RK
Environmental Protection Agency, National Environmental Research Center, Research Triangle Park, N. C.
Krost, KJ
Environmental Protection Agency, National Environmental Research Center, Research Triangle Park, N. C.
Related
Reprints and Permissions
Details
Developed by Committee: D22
Pages: 101–111
DOI: 10.1520/STP38970S
ISBN-EB: 978-0-8031-5582-4
ISBN-13: 978-0-8031-0376-4