SYMPOSIA PAPER
Published:
01 January 1973
STP36491S
Some Important Aspects in Testing High-Modulus Fiber Composite Tubes in Axial Tension
SourceTubular specimens were potted in metal grips to determine the feasibility of this gripping method in applying multiaxial loads. Strain gage rosettes were used to assess grip transitional strains, through thickness strain variation and strain variations along the tube length and circumference. The investigation was limited to loading 0, 45, ±45, and 90-deg graphite/epoxy and glass/epoxy tubes in axial tension. Results include modifications made to the grips to reduce transitional strains, illustrations of the tube failure modes, and some material properties. The gripping concept shows promise as a satisfactory technique for applying multiaxial loads to high-strength, high-modulus fiber composite tubes.
Author Information
Sullivan, TL
Lewis Research Center, National Aeronautics and Space Administration, Cleveland, Ohio
Chamis, CC
Lewis Research Center, National Aeronautics and Space Administration, Cleveland, Ohio
Related
Reprints and Permissions
Details
Developed by Committee: D30
Pages: 277–292
DOI: 10.1520/STP36491S
ISBN-EB: 978-0-8031-4621-1
ISBN-13: 978-0-8031-0701-4