SYMPOSIA PAPER
Published:
01 January 1985
STP36383S
Development of the Volatile Organic Sampling Train for Use in Determining Incinerator Efficiency
SourceDevelopment and field application are described for the volatile organic sampling train (VOST) for testing incinerator efficiency. The concepts behind the VOST, several stages in its development, and the current status of this technology are discussed. Early experience indicates that the VOST works well in the field and yields good results when used with adequate care and precautions.
Author Information
Johnson, LD
Air and Energy Engineering Research Laboratory, U.S. Environmental Protection Agency, Research Triangle Park, NC
Related
Reprints and Permissions
Details
Developed by Committee: D34
Pages: 335–343
DOI: 10.1520/STP36383S
ISBN-EB: 978-0-8031-4950-2
ISBN-13: 978-0-8031-0430-3