Heat Transfer Versus Pitch Angle for Nonventilated, Triangular-Sectioned, Apex-Upward Air-Filled Spaces
SourceThe optimal pitch angle of a nonventilated triangular-sectioned air space, corresponding to a minimum heat transfer (Q) versus pitch angle (θ), was experimentally determined on a laboratory model to be 18 deg inclination for small values of temperature difference (ΔT) appropriate to those that would occur in roof spaces. In a more realistic roof cavity, this optimal pitch would be smaller; it is suggested that full-size nonventilated roofs be designed with pitches near 15 deg.
Author Information
Thirst, TJ
School of Mechanical Engineering, Cranfield Institute of Technology, Bedford, England
Probert, SD
School of Mechanical Engineering, Cranfield Institute of Technology, Bedford, England
Related
Reprints and Permissions
Details
Developed by Committee: C16
Pages: 203–210
DOI: 10.1520/STP35745S
ISBN-EB: 978-0-8031-4729-4
ISBN-13: 978-0-8031-0589-8