SYMPOSIA PAPER
Published:
01 January 1980
STP35091S
Discrepancies Between Film and Thermoluminescent Dosimetry (TLD) Readings at an Operating Power Reactor
SourceThe results of exposure measurements using film badges and thermoluminescent dosimetry (TLD) were compared at an operating nuclear power reactor. The film badge overresponded to the high-energy Nitrogen-16 gamma rays produced under power, while the TLD did not. Discussions of charged-particle equilibrium and energy dependence are included. The cause of the overresponse was determined to be the excess pair production electrons created because of the high atomic number in the lead energy-compensating shield surrounding the film and in the film itself.
Author Information
Quinn, DM
Power Authority of the State of New York, Indian Point No. 3 Nuclear Power Plant, Buchanan, N.Y.
Related
Reprints and Permissions
Details
Developed by Committee: D22
Pages: 31–37
DOI: 10.1520/STP35091S
ISBN-EB: 978-0-8031-4769-0
ISBN-13: 978-0-8031-0329-0