SourceThe acoustic emission (AE) monitoring of a steam drum-boiler interface in a CANdu nuclear generating station is described. The component was monitored during both the initial hydrostatic test and a load rejection test. Results obtained were not in complete agreement with those previously presented in the literature. Examination of the three-detection method of source location reveals part of the cause of this discrepancy. Other potential mechanisms for the generation of non-locatable AE events are discussed.
Author Information
Baron, JA
Ontario Hydro Research Division, Toronto, Canada