Detection Systems for Neutron Radiography
SourceImage detection methods for neutron radiography are described and capabilities of the methods in terms of exposure requirements, spatial resolution, and contrast are given. Neutron energy ranges cold, thermal, epithermal, and fast are included, but emphasis is on detectors for thermal neutron images. Image methods include photographic film, real-time, track-etch, gas-cell, and thermoluminescent; major emphasis is on film techniques, both direct exposure and transfer.
Author Information
Berger, H
Institute for Materials Research, National Bureau of Standards, Washington, D.C.
Related
Reprints and Permissions
Details
Developed by Committee: E07
Pages: 35–57
DOI: 10.1520/STP33910S
ISBN-EB: 978-0-8031-4668-6
ISBN-13: 978-0-8031-0535-5