This paper describes the process employed in defining and creating an integrated instrument with computing and recording capability that generates a document containing a full chromatogram juxtaposed with its quantitative on-line analysis. This selfcontained system, called the GC Computing Recorder, operates from the raw gas chromatograph detector signal through appropriate signal conditioning, analog-to-digital conversion, microcomputer-based digital integration and postintegration calculation to generate the final analytical report, termed the integrated chromatogram.
The paper briefly reviews the historical development of gas chromatographic quantitation technology and it postulates the system requirements for single channel quantitation instrumentation. Then, it summarizes the specific design approaches considered for the computing recorder, the evolution of the system architecture from the point of view of its inputs and outputs, and the selection of the architectural approach adopted for the final design. Particular attention is devoted to man/machine interface considerations, signal conditioning design, digital filtering, analog-to-digital conversion techniques, and firmware integration treatments.
Criteria developed to enhance the integration portion of the system firmware are explored, and the algorithmic treatments of overlapping peaks, drifting baselines, area recovery, and multiple peak resolution are discussed. The detailed systems description also covers the areas of postintegration calculations including area normalization, response factors, and relative retention times, as well as the application of internal standard methods for precision determinations of component concentration levels.
Experience with the instrument under actual laboratory conditions is summarized, and observations are made concerning possible system extensions.
Author Information
Zawadowicz, ST
Process Control Division/Fort Washington, Honeywell Inc., Fort Washington, Pa.
Kegg, AL
Process Control Division/Fort Washington, Honeywell Inc., Fort Washington, Pa.
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.