SYMPOSIA PAPER
Published:
01 January 1985
STP32911S
Surface Temperature Sensor Calibration: Technique
SourceThe surface temperature dectors on a guarded hot plate can be calibrated in place using differential thermopiles. A ten-junction Type T thermopile was used to calibrate a 1.22-m (4-ft) guarded hot plate using water triple point cells as the reference temperature. The stability and precision of these thermopiles, over a year's span, was on the order of 20 to 30 millidegrees.
Author Information
Schumann, SP
Technical Center, Owens Corning Fiberglas, Granville, OH
Related
Reprints and Permissions
Details
Developed by Committee: C16
Pages: 220–226
DOI: 10.1520/STP32911S
ISBN-EB: 978-0-8031-4944-1
ISBN-13: 978-0-8031-0423-5