Surface preparation and corrosion behavior of titanium alloys were studied; both topics deal with the formation of surface oxide films. When metals are prepared for surgical implant use, an effort is made to produce an optimum surface. Effects of the surface treatments on surface morphology, surface film composition, and structure are shown in transmission electron photomicrographs and electron diffraction patterns. Roughened surfaces were produced, and surface films of titanium oxide (TiO) or titanium dioxide (TiO2) or both occurred on some specimens. Sodium titanate (NaO · xTiO2) occurred on the specimens washed in sodium hydroxide (NaOH) solution.
Open circuit potential versus time curves have been measured to show some electrochemical effects of various surface treatments. The results show that titanium alloys immersed in Hanks' physiological solution reach the same final open-circuit potential after approximately two weeks' exposure regardless of prior surface treatment. Measurements of the anodic polarization behavior of titanium alloys and other surgical implant alloys show the effects of alloy composition and the testing solution on the passive region and breakdown potentials of these materials. In general, for titanium alloys, the differences are not great, but the presence of nickel results in a significant lowering of the breakdown potential. The materials studied were titanium, Ti-6Al-4V, titanium-nickel (memory alloy), Ti-13Cu-4Ni, and Ti-4.5Al-5Mo-1.5Cr. In all cases titanium materials are more corrosion resistant in Hanks' solution than cobalt-chromium-molybdenum Type 316L stainless steel, or cobalt-nickel-chromium alloys. Repassivation measurements show the rapid formation and the high degree of stability of the protective film on titanium and titanium alloys.
Author Information
Fraker, AC
National Bureau of Standards, Washington, D.C.
Ruff, AW
National Bureau of Standards, Washington, D.C.
Sung, P
Food and Drug Administration, Silver Spring, Md.
Van Orden, AC
National Bureau of Standards, Washington, D.C.
Speck, KM
Unifomed Services University Medical School, Bethesda, Md.
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.