Formulation and Validation of an Attic Ventilation Algorithm Used for Conducting a Parametric Study of the Variables Affecting the Thermal Performance of Radiant Barrier Systems Installed in Soffit-to-Ridge Ventilated Attics

Source

A computational fluid dynamics (CFD) code was used to formulate and benchmark an algorithm that predicts the wind- and buoyancy-driven airflows in soffit-to-ridge ventilated attics. Computations were benchmarked against field measures for a conventional soffit-to-ridge ventilated attic that was part of the Natural Exposure Test (NET) facility in Charleston, SC. Researchers coded the algorithm into the computer tool AtticSim and benchmarked the tool against attic floor heat flows measured on the NET. A parametric analysis followed to study the variables affecting the thermal performance of radiant barriers with thermal emittance ranging from 0.03 to 0.90. Results were organized in a database documenting the reduction in heat load due to radiant barrier and attic insulation materials. Building America Climate Zones 1 through 6 and California Climate Zones 7, 11, 12, and 15 were investigated for ceiling insulation levels ranging from no insulation (only gypsum board) to a well-insulated cold climate application. Control simulations were made with the duct in the conditioned space and with the duct in the attic. Air leakage for ducts in the attic was 0% (no leakage in attic) and 5% (near the prescriptive code) of the supply airflow. Simulations showed that adding a radiant barrier of 0.03 or 0.05 thermal emittance to an attic with RSI 3.35 insulation on the attic floor yielded the same savings as increasing insulation from RSI 3.35 to RSI 6.69 for an attic with no radiation control. The hotter the climate, the more the trade-off favored radiant barrier systems. ASHRAE published an algorithm for estimating the air temperature of an unconditioned space that is adjacent to conditioned spaces. The ASHRAE formulation was compared to AtticSim and field measures for predicting the attic air temperature. The routine predicted both field and simulation measures that showed consistency between the two approaches.

Author Information

Miller, William
MABE Dept., University of Tennessee, Knoxville, TN, US
Childs, Kenneth
ORNL (retired), Knoxville, TN, US
Price: $25.00
Contact Sales
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Pages: 161–176
DOI: 10.1520/STP165720240046
ISBN-EB: 978-0-8031-7766-6
ISBN-13: 978-0-8031-7765-9