The presence of taper junctions in hip arthroplasty designs has been suggested to contribute to premature clinical failure, in part due to corrosion-assisted material loss. Characterization of the material loss at the taper junction is an important factor in determining not only taper performance but also the requirement for revision of primary stems. It is therefore clear that a robust metrological solution to this issue is required to understand the connection between damage to the stem surface and explicit criteria to initiate retrieval. Previously detailed studies have focused on the characterization of tapers with plain-machined surfaces, with most research concentrated on femoral head tapers. This study details a measurement and analysis method to characterize threaded-type microgroove trunnion surfaces that make up a large proportion of current implanted stem taper designs. Femoral stem designs from two manufacturers were measured using a Talyrond 365 (Ametek, Inc., Berwyn, PA) out-of-roundness measurement machine. Submicron measurement resolution was achieved, and the use of a 5-µm radius diamond stylus meant that any mechanical filtering effect was insignificant compared to conventional contact measurement techniques. The grooved topography of the trunnion surface presents challenges in ascertaining an “unworn” surface from which surface damage data are then separated. A novel filter was developed to delineate form and material loss. The filter is responsive such that the wavelength and amplitude of an individual component’s microgrooves can be removed from the analysis. Application of the filter to leveled data allowed bearing area analysis to be utilized to determine an accurate volume of material loss based on the residual form-removed data. A cohort of as-manufactured samples (n = 21) were measured and used to validate the filtering methodology. A component exhibiting induced surface wear (n = 1) was measured using the same instrumentation and processed using the filtering technique.
Author Information
Dransfield, Karl
EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, GB
Racasan, Radu
EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, GB
Blunt, Liam
EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, GB
Bills, Paul
EPSRC Future Advanced Metrology Hub, University of Huddersfield, Huddersfield, GB
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.