When used as implant material in joint arthroplasty or trauma surgery, titanium and its alloys are subjected to dynamic in vivo loading conditions. In the case of an inappropriate design or an unforeseen loading event, breakage of the metal component might occur. This is a rare (<1 % in total hip arthroplasty) but serious complication, and it requires special attention for revision surgery. Titanium and its alloys, such as Ti-6Al-4V, which was used in this study, can be considered as the most corrosion resistant of the orthopedic metals used today. However, the influence of a corrosive medium on fatigue strength during cyclic loading has not yet been fully investigated. In order to enhance the fatigue strength, mechanical surface treatments have been applied to some implant designs, in particular revision hip systems. Therefore, specimens that had been shot peened in a two-step procedure (high-intensity cut wire peening and low-intensity cleaning by glass beads) were used for fatigue testing to a maximum of 10 × 106 cycles at 10 Hz (R = 0.1) under two conditions: (a) in a dry atmosphere (room conditions) and (b) circulated by a corrosive saline solution. Notable increases in fatigue strength were found in both cases after shot peening relative to untreated (annealed) specimens, and this has been associated with the introduction of high residual stresses at the surface. Even though no differences were seen at 10 × 106 cycles, the influence of a corrosive environment might be relevant at higher loads.
Author Information
Sonntag, Robert
Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, DE
Reinders, Joern
Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, DE
Gibmeier, Jens
Institute of Applied Science, Karlsruhe Institute of Technology (KIT), Karlsruhe, DE
Jaeger, Sebastian
Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, DE
Kretzer, J., Philippe
Laboratory of Biomechanics and Implant Research, Heidelberg University Hospital, Heidelberg, DE
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.