Neutron Spectrum Measurements in SEG-V Benchmark System
SourceThe SEG-V configuration in the RRR reactor is a benchmark system with an energy-independent adjoint flux spectrum. The neutron spectrum has been measured by means of proton recoil counters, a Stilbene scintillation technique, and a Li6 sandwich spectrometer. A set of activation and fission reaction rate measurements has been unfolded by the SAND-II program. The experimental results are compared with a two-dimensional spectrum calculation. Good agreement has been obtained in the most important energy range.
Author Information
Ošmera, B
Nuclear Research Institute (ÚJV), ŘeŽ, Czechoslovakia
Racek, J
Nuclear Research Institute (ÚJV), ŘeŽ, Czechoslovakia
Turźik, Z
Nuclear Research Institute (ÚJV), ŘeŽ, Czechoslovakia
Hansen, W
Central Institute for Nuclear Research (ZfK), Dresden, Federal Republic of Germany
Vogel, W
Central Institute for Nuclear Research (ZfK), Dresden, Federal Republic of Germany
Related
Reprints and Permissions
Details
Developed by Committee: E10
Pages: 333–339
DOI: 10.1520/STP10092S
ISBN-EB: 978-0-8031-5069-0
ISBN-13: 978-0-8031-1184-4