Journal Published Online: 17 December 2004
Volume 27, Issue 1

Tensile Test Method Effect on the Tensile Strength of Flexible PET Geogrids

CODEN: GTJODJ

Abstract

For single rib tensile tests using GRI-GG1, the ultimate and 5 % strain tensile strengths obtained from tests with an extension rate of 50 mm/min are greater than those obtained using a 10 mm/min extension rate. However, the elongation at the break occurs in reverse order. For wide-width tensile tests using ASTM D4595, the unit tensile strengths and elongations at break decrease as the number of specimen ribs increases. The repeatability of the test results decreases as the number of ribs increases. The tensile strengths obtained from wide-width tensile tests are 1–8 % less than those obtained using GRI-GG1. The elongation at the break is about 92–99 % of that obtained using GRI-GG1. Rib breakage at peak load is randomly distributed for different specimens and samples.

Author Information

Hsieh, CW
National Pingtung University. of Science and Technology, Neipu, Pingtung, Taiwan
Lin, CK
National Pingtung University of Science and Technology, Taiwan
Pages: 8
Price: $25.00
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Stock #: GTJ11265J
ISSN: 0149-6115
DOI: 10.1520/GTJ11265J