Friction at the Cohesionless Soil-Structure Interface: Effect of Various Parameters according to a Classic Study and a New Approach

CODEN: GTJODJ

Abstract

A direct shear box, a ring shear apparatus, and a minipressuremeter are used: (1) to study the behavior of the cohesionless soil-structure interface; (2) to evaluate the friction mobilized at this interface. Tests have been carried out with a continual displacement of the structure in contact with the soil. The applied normal stress was kept constant during all tests. The influence of the mineralogy, the initial density, and the roughness are analyzed. The tests show that it is difficult to obtain identical laboratory results with different apparatus. It is necessary to validate these apparatus with the help of a comparison of in situ results. Once this validation is done, especially for the mini-pressuremeter, it is reasonable to consider the mini-pressuremeter for calibrating the structure in cohesionless soils.

Author Information

Abderrahim, A
Laboratoire de Géomécanique, Ecole Nationale Supérieure de Géologie, Vandœuvre, France
Tisot, JP
Laboratoire de Géomécanique, Ecole Nationale Supérieure de Géologie, Vandœuvre, France
Pages: 9
Price: $25.00
Related
Reprints and Permissions
Reprints and copyright permissions can be requested through the
Copyright Clearance Center
Details
Stock #: GTJ10275J
ISSN: 0149-6115
DOI: 10.1520/GTJ10275J