Standard
Historical
Last Updated: Aug 16, 2017
Track Document
ASTM E360-96
Standard Test Methods for Chemical Analysis of Silicon and Ferrosilicon
Standard Test Methods for Chemical Analysis of Silicon and Ferrosilicon
E0360-96
ASTM|E0360-96|en-US
Standard Test Methods for Chemical Analysis of Silicon and Ferrosilicon
Standard
E360 Standard Test Methods for Chemical Analysis of Silicon and Ferrosilicon>
new
BOS Vol. 03.05 Committee E01
$
86.00
In stock
Scope
DESIG: E360 96 (Reapproved 2001) ^TITLE: Standard Test Methods for Chemical Analysis of Silicon and Ferrosilicon ^SCOPE:
1.1 These test methods cover the chemical analysis of silicon and ferrosilicon having chemical compositions within the following limits:
| Element | Concentration, % |
| Aluminum | 2.0 max |
| Arsenic | |
| Calcium | 1.00 max |
| Carbon | 0.50 max |
| Chromium | 0.50 max |
| Copper | 0.30 max |
| Manganese | 1.00 max |
| Nickel | 0.30 max |
| Phosphorus | 0.10 max |
| Silicon | 20.00 to 99.5 |
| Sulfur | 0.025 max |
| Titanium | 0.20 max |
1.2 The test methods appear in the following order:
| Sections | |
| Arsenic by the Molybdenum Blue Photometric Method | |
| Aluminum by the Quinolinate Photometric and GravimetricMethods | |
| Silicon by the Sodium Peroxide Fusion-Perchloric Acid Dehydration Method |
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 5 and 26.8.1, 27.4.1.1, and 36.3.1.