Standard Guide for Sampling and Reporting of Results for Determination of Biobased Content of Materials via Carbon Isotope Analysis (Withdrawn 2020)
Standard Guide for Sampling and Reporting of Results for Determination of Biobased Content of Materials via Carbon Isotope Analysis (Withdrawn 2020)D7026-13ASTM|D7026-13|en-USStandard Guide for Sampling and Reporting of Results for Determination of Biobased Content of Materials via Carbon Isotope Analysis (Withdrawn 2020)StandardD7026 Standard Guide for Sampling and Reporting of Results for Determination of Biobased Content of Materials via Carbon Isotope Analysis (Withdrawn 2020)>newBOS Vol. 08.03 Committee D20
$0.00
Out of stock
Significance and Use
4.1 The carbon isotope analysis is designed to be an adjunct to other information in determination of biobased content, specifically the manufacturer’s records. It is also a means of verifying the authenticity of a disputed lot of material which may be manufactured by different means, from different raw materials. FTIR or other chemical analysis means will identify the molecule as being ethanol, but not give indication of the source (that is, fossil carbon versus modern carbon). The carbon isotopes will give both indication of source and the presence of a mixture of sources.
4.2 Representative sampling and handling methods are clearly a prerequisite to obtaining accurate results from the radiocarbon composition determination and any other quantitative analytical method.
4.3 This guide provides for accurate and complete reporting of the sample collection, handling, chain of custody, sample preparation and treatment that allows any independent party to assess the validity of the reported biobased content of the material.
Scope
1.1 This guide provides a framework for collecting and handling samples for determination of biobased content of materials by means of the carbon isotope method described in Test Methods D6866. Tests for sampling adequacy based on the standard statistical tools are provided. In addition, reporting of the results, including sampling techniques and handling procedures and chain-of-custody issues are discussed.
1.2 This guide is concerned with collecting representative samples within a given material or a lot, not with lot-to-lot variations such as considered in quality control schemes.
1.3 Biobased materials often represent sampling problems specific to a given material, such as heterogeneity, and so forth, which require employment of material-specific sampling methods. The use of specialized sampling methods already accepted and validated by industries that manufacture and/or use the biomaterial is encouraged. However, all sampling techniques, especially non-standard techniques developed for specific materials must be reported in sufficient detail to allow critical assessment of the techniques used.
1.4 Carbon isotope analysis involves thermal processing in presence of oxidants. Compatibility of any given material with Test Methods D6866 must be assessed. Special attention must be given to materials with potential for explosion hazards, such as peroxides, nitrated compounds, azides, and so forth. Examples of peroxide-forming compounds are ethers, some ketones and a number of other compounds.
1.5 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.
1.6 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory requirements prior to use.
Note 1—There is no known ISO equivalent to this standard.
Language unavailable
Format unavailable
What is a Redline?
Why Redline?
A PDF redline is a quick and easy way to compare all of the changes between the current, active standard and the previous version.
With a redline you'll immediately see:
additions
deletions
and other changes between the two standards.
Save Time and Trouble!With a Redline you no longer have to spend time trying to determine what has changed in the new standard! Redlines save you time and ensure you see what the changes are to the standard.
PriceWhen you select the "Standard + Redline" option you get both documents! Best of all, the cost of a Standard + Redline is only slightly more than buying the Active Standard by itself.
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.