Standard Practice for Etching and Cleaning Copper-Clad Electrical Insulating Materials and Thermosetting Laminates for Electrical Testing (Withdrawn 2012)D1825-03ASTM|D1825-03|en-USStandard Practice for Etching and Cleaning Copper-Clad Electrical Insulating Materials and Thermosetting Laminates for Electrical Testing (Withdrawn 2012)StandardD1825 Standard Practice for Etching and Cleaning Copper-Clad Electrical Insulating Materials and Thermosetting Laminates for Electrical Testing (Withdrawn 2012)>newBOS Vol. 10.01 Committee D09
$0.00
Out of stock
Significance and Use
The procedure used for etching the copper foil from the base insulating materials may significantly affect the results of electrical tests. This is true primarily for two reasons. First, the geometry of the copper which remains and forms the electrodes is in part determined by the etching procedure; this is particularly true of closely spaced electrodes on the same surface when the property to be measured depends on the electrode geometry. Second, electrical conductance in the material, particularly surface conductance, may be affected by the chemicals used to etch the copper, the length of time of etching, and the manner in which the specimen is cleaned after etching.
This practice standardizes the etching procedure in order to provide a basis for comparison of electrical properties of copper-clad electrical insulating materials and thermosetting laminates. Experience has shown that the test circuit can be accurately prepared using this procedure, and that the specimen will be substantially free of etching-induced, electrically-conductive contaminants.
It is recognized that commercial processes utilized to manufacture printed circuits may differ appreciably from this practice. Therefore, the results of tests on specimens etched in accordance with this practice may differ from results obtained on specimens etched in a commercial process. Specimens should be etched in accordance with a procedure different from this practice, if it is desired to determine the influence of the different procedure on electrical properties.
Scope
1.1 This practice describes a procedure for etching and cleaning copper-clad electrical insulating materials and thermosetting laminates for electrical testing.
1.2 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specific warning statements see 6.3 and 6.4.
Language unavailable
Format unavailable
What is a Redline?
Why Redline?
A PDF redline is a quick and easy way to compare all of the changes between the current, active standard and the previous version.
With a redline you'll immediately see:
additions
deletions
and other changes between the two standards.
Save Time and Trouble!With a Redline you no longer have to spend time trying to determine what has changed in the new standard! Redlines save you time and ensure you see what the changes are to the standard.
PriceWhen you select the "Standard + Redline" option you get both documents! Best of all, the cost of a Standard + Redline is only slightly more than buying the Active Standard by itself.
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.