Standard Practice for Sampling Aluminum Ingots, Billets, Castings and Finished or Semi-Finished Wrought Aluminum Products for Compositional Analysis
Standard Practice for Sampling Aluminum Ingots, Billets, Castings and Finished or Semi-Finished Wrought Aluminum Products for Compositional AnalysisB0985-12ASTM|B0985-12|en-USStandard Practice for Sampling Aluminum Ingots, Billets, Castings and Finished or Semi-Finished Wrought Aluminum Products for Compositional AnalysisStandardB985 Standard Practice for Sampling Aluminum Ingots, Billets, Castings and Finished or Semi-Finished Wrought Aluminum Products for Compositional Analysis>newBOS Vol. 02.02 Committee B07
$86.00
In stock
Significance and Use
5.1 Products covered by this practice are unwrought aluminum ingots, billets, and castings and unclad wrought aluminum sheet, plate, rolled or cold finished extrusions, extruded profiles, wire, rod and bar. Machined wrought products (finished or semi-finished) are excluded (see Note 3). These practices, used in conjunction with the appropriate sample preparation techniques in E716 and the Test Methods E34, E607, E1251, and EN 14242, are suitable to determine if the piece sampled meets the chemical composition limits registered with the Aluminum Association Inc.5 or other specified chemical composition limits for the alloy. Analysis of such samples shall not supersede the analysis of samples taken during pouring of castings or ingots in accordance with E716 and analyzed in accordance with E607, E1251, E34, or EN 14242 and shall not be used for determining compliance with chemical composition requirements for an entire cast lot or part thereof.
Note 3—Sampling machined pieces of products pose a particular problem because the piece itself may not be a representative sample of the original cast chemical composition. Larger differences may be expected between an analysis obtained from samples taken in accordance with this practice and the original cast analysis of samples taken during pouring of castings or ingot.
Note 4—Portable Spark-AES and hand held XRF instruments should not be used to determine if the piece sampled meets chemical composition limits registered with Aluminum Association Inc or other specified chemical composition limits for the alloy.
5.2 Users should be aware that chemical compositions determined using samples taken from unwrought aluminum ingots, billets, and castings and finished or semi-finished products might differ from the bulk chemical composition determined using samples taken when ingots or castings are poured. This difference can be due to elemental segregation upon solidification, sampling a non-homogenous section of the ingot or billet, removal of enriched material, or depleted areas of solidified material by subsequent procedures such as ingot scalping, the removal of risers from castings, or machining.
Note 5—When aluminum solidifies, macro-segregation may cause the chemical composition to vary throughout the ingot or casting. Certain areas may have enhanced or depleted concentrations of some elements relative to the average bulk chemical composition. Remnants of the macro-segregation may be retained in finished and semi-finished products. The sampling procedures described in this practice are designed to provide a laboratory sample for analysis which represents the chemical composition of the piece by taking samples in a way that symmetrically includes the various enhanced and depleted zones e.g. sampling across the radius of a round ingot etc.
Scope
1.1 This practice describes procedures for sampling unwrought aluminum ingots, billets, castings and finished or semi-finished wrought aluminum products to obtain a representative sample for determining chemical composition.
1.1.1 Chemical compositions determined from samples obtained in accordance with this standard practice may differ from the bulk chemical composition determined from samples taken when ingots or castings are poured. These differences can be due to elemental segregation that occurs during solidification, procedures that remove enriched material (e.g. ingot scalping), or procedures that remove depleted areas (e.g. removal of the riser from a casting).
1.1.2 Analysis of samples obtained from unwrought aluminum ingots, billets, and castings and finished or semi-finished wrought aluminum products can be used to determine if the piece sampled meets The Aluminum Association, Inc. registered chemical composition limits or other specified chemical composition limits for the alloy. Analysis of such samples shall not supersede the analysis of samples taken during pouring of castings or ingots in accordance with E716 and analyzed in accordance with E607, E1251, E34, or EN 14242 and shall not be used for determining compliance with chemical composition requirements for an entire cast lot or part thereof.
Note 1—Pieces may include ingots, forgings, coils, sheets, extrusions, castings, etc. A single unwrought ingot or billet may produce multiple finished or semi-finished pieces.
Note 2—Certification of entire cast lots should be determined using samples taken during pouring of castings or ingots in accordance with E716 and analyzed in accordance with E607, E1251, E34, or EN 14242.
1.2 Units—The values stated in either SI units or inch-pound units are to be regarded separately as standard. The values stated in each system may not be exact equivalents; therefore, each system shall be used independently of the other. Combining values from the two systems may result in non-conformance with the standard.
1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.