Standard Specification for Copper, Copper-Alloy, Copper-Clad Bronze (CCB), Copper-Clad Stainless Steel (CCS), and Copper-Clad Alloy Steel (CAS) Sheet and Strip for Electrical Cable ShieldingB0694-13ASTM|B0694-13|en-USStandard Specification for Copper, Copper-Alloy, Copper-Clad Bronze (CCB), Copper-Clad Stainless Steel (CCS), and Copper-Clad Alloy Steel (CAS) Sheet and Strip for Electrical Cable ShieldingStandardB694 Standard Specification for Copper, Copper-Alloy, Copper-Clad Bronze (CCB), Copper-Clad Stainless Steel (CCS), and Copper-Clad Alloy Steel (CAS) Sheet and Strip for Electrical Cable Shielding>newBOS Vol. 02.01 Committee B05
$86.00
In stock
Abstract
This specification establishes the requirements for sheets and strips of various thicknesses produced from copper (Copper UNS No. C1000), copper-iron alloy (Copper Alloy UNS No. C19400), copper-zinc alloy that is commercial bronze (Copper Alloy UNS No. C22000), copper-zinc alloy that is red brass (Copper Alloy UNS No. C23000), copper-zinc-iron-cobalt alloy (Copper Alloy UNS No. C66400), copper-zinc-iron alloy (Copper Alloy UNS No. C66410), copper-zinc-iron-tin alloy (Copper Alloy UNS No. C66430), cupro-20% nickel (Copper Alloy UNS No. C71000), copper-clad bronze, copper-clad stainless steel, and copper-clad alloy steel. These materials are intended for use as electrostatic or electromagnetic shielding for insulated power, control, instrumentation, and communication cables. Cladding metals may be bonded to the specified base metal by any method that will produce products that will conform to the properties and characteristics prescribed herein. Materials shall be furnished specific to individual metals in the following tempers: H00 (cold-rolled, 1/8 hard), H01 (cold-rolled, ¼ hard), H02 (cold-rolled, ½ hard); O61 (annealed), O81 (annealed, ¼ hard), O50 (light annealed), O61 (annealed, soft), OS035, and OS015. Specimens shall be sampled and prepared, then tested accordingly to examine their conformance to dimensional (mass, thickness, width, straightness, and cladding ratio), mechanical (tensile strength, and Rockwell hardness), electrical (mass resistivity, and conductivity), chemical composition, and grain size requirements.
Scope
1.1 This specification establishes the requirements for copper, copper alloy, copper-clad bronze (CCB), copper-clad stainless steel (CCS), and copper-clad alloy steel (CAS) materials, sheet, and strip, in various thicknesses, for use as electrostatic or electromagnetic shielding for insulated power, control, instrumentation, and communication cables.
Note 1—See Specification B736, for related standards for aluminum-based shielding materials.
1.2 The products covered are the following:
Copper or Copper Alloy UNS No.
Type of Products
C11000
copper
C19400
copper-iron alloy
C22000
copper-zinc alloy (commercial bronze)
C23000
copper-zinc alloy (red brass)
C66400
copper-zinc-iron-cobalt alloy
C66410
copper-zinc-iron alloy
C66430
copper-zinc-iron-tin alloy
C71000
cupro-nickel 20 %
...
copper-clad bronze (CCB)
...
copper-clad stainless steel (CCS)
...
copper-clad alloy steel (CAS)
1.3 The values stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematical conversions to SI units that are provided for information only and are not considered standard.
1.3.1 The only exception is grain size, which is reported in SI (mm) units.
1.4 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Domestic orders are delivered via United Parcel Service (UPS) or United States Postal Service (USPS). Transit
times average 3 to 5 business days. Please be aware that UPS will not deliver packages to Post Office Boxes.
International orders are delivered via courier post services which can be either a postal service, courier
service, or a combination of both. Standard Service is untraceable. Please allow 4-7 weeks for delivery.
Please be aware that carriers will not deliver packages to Post Office Boxes. Because of the variability of
customs processes and procedures in different countries, ASTM International cannot guarantee transit times to
international destinations. Customs duty and taxes are the responsibility of the consignee.
Shipping & Handling charges follow the rate schedule, below:
Order Total
Shipping & Handling Fee (US Domestic)
Up to $50.00
$18.72
$50.01 to $100.00
$20.80
$100.01 to $150.00
$29.52
$150.01 to $250.00
$39.09
$250.01 to $500.00
$56.25
$500.01 to $750.00
$76.42
$750.01 to $1000.00
$93.15
$1000.01 to $1500.00
$121.27
$1500.01 to $2500.00
$158.38
$2500.01 to $4999.00
$209.04
$5000.00 to higher
FREE
Order Total
Shipping & Handling Fee (International)
Up to $50.00
$68.72
$50.01 to $100.00
$70.80
$100.01 to $150.00
$79.52
$150.01 to $250.00
$89.09
$250.01 to $500.00
$106.25
$500.01 to $750.00
$126.42
$750.01 to $1000.00
$143.15
$1000.01 to $1500.00
$171.27
$1500.01 to $2500.00
$208.38
$2500.01 to $4999.00
$259.04
$5000.00 to higher
FREE
Shipping and Handling charges are approximate. Additional charges may be incurred if your order requires multiple shipments. This does not apply to complete sets and sections.